Heat recovery unit
-
DESCRIPTION
General features0
Double flow ventilation unit made with external galvanized steel sheet and high-efficiency cross flow
heat recovery unit.Suitable to ventilate small and medium-size rooms in tertiary and commercial sectors such as pubs, restaurants, offices, meeting rooms, shops, gyms, dance halls, canteens, etc.
Equippaed with cross-flow high efficiency heat exchangers from 73% to 88%
- Equipped with EC (high efficiency) electrical fans.
- Forward bladed double inlet fans, installed in Models of size 1600 and greater, already comply with both IE5 and ERP2020 efficiency limits.
- External structure in galvanized steel sheet;
- Thermal and acustic isolation with 23 mm thick polyurethane (40 Kh/m³);
- Motors can be adjusted separately;
- Two temperature probes: first probe for the delivery air and second probe for the return air;
- Motorized internal by-pass shutter adjustable both manually and automatically;
- Pressure-switch to measure the filter stoppage level
- Control board set to connect a C02 or humidity probe (optional);
- Equipped electric control board is IP 55 protected;
- Centrifugal fans with reverse blades (UVR-HE 500, UVR-HE 700, UVR-HE 1200 Models);
- Centrifugal fans with forward blades (from UVR-HE 1600 to UVR-HE 8500 Models);
- Equipped with an rs485 port that allows:
– connection to a single “DeG” remote controller;
– full compatibility with the MODBUS interface;
– up to six base controllers can be linked together using a cascade connection and be
managed using a single “DeG” remote controller. - Filters can be easily inspected and replaced through proper portholes placed on the unit cover;
- M6 filter for the external exhaust air;
- FT filter for the renewal delivery air;
- Aeraulic configuration can be implemented also in the building site;
- Remote control unit included;
- Mounting brackets included;
- Insulator with fireproof sound-absorbing mattress placed on the lower and upper panels;
- Condensation collection tray including condensate drain.
REMOTE CONTROL UNIT:
- Remote control unit with monochrome display;
- Remote control of the UVR-HE units with manual or automatic functioning;
- Flush mounting in 3-module boxes (503 type);
- LED light to indicate the filter stoppage status;
- Manual and automatic by-pass control;
- Control of the two fans in coupled or separate mode;
- Detection of the external and internal temperatures;
- Fan mode control according to C02 air quality (optional);
ACCESSORIES:
- Post-heating hydronic batteries;
- Post-cooling hydronic batteries;
- Pre and post-heating electric batteries;
-
ADVANTAGES
0
Double flow ventilation unit made with external galvanized steel sheet and high-efficiency cross flow
heat recovery unit.Suitable to ventilate small and medium-size rooms in tertiary and commercial sectors such as pubs, restaurants, offices, meeting rooms, shops, gyms, dance halls, canteens, etc.
Equippaed with cross-flow high efficiency heat exchangers from 73% to 88%
Advantages -
TECHNICAL SPECIFICATION
CODE MODEL m³/h max. Pa
max.Nominal
flow rate
QnomW A V~ Hz Ph Class dB at 2mt AP20071 UVR 500 MF HE 650 470 620 2×160 2×1,18 230 50/60 1 51 46 AP20073 UVR 700 MF HE 750 470 720 2×140 2×1,07 230 50/60 1 51 46 AP20075 UVR 1200 MF HE 1200 600 1120 2×240 2×1,5 230 50/60 1 51 46 AP20077 UVR 1600 MF HE 1600 750 1580 2×360 2×2,2 230 50/60 1 59 53 AP20079 UVR 2300 MF HE 2300 500 1780 2×1070 2×4,6 230 50/60 1 60 55 AP20081 UVR 2800 MF HE 2800 650 2160 2×1070 2×4,6 230 50/60 1 61 56 AP20083 UVR 3200 MF HE 3200 650 2540 2×1040 2×4,5 230 50/60 1 62 56 AP20085 UVR 3800 MF HE 3800 800 2760 2×1040 2×4,5 230 50/60 1 62 56 AP20087 UVR 4500 MF HE 4500 650 2680 2×2200 2×5,6 230 50/60 1 63 57 AP20089 UVR 5400 MF HE 5400 830 4780 2×2200 2×8,6 230 50/60 1 64 59 AP20091 UVR 6500 MF HE 6500 1200 4880 2×2310 2×9,4 230 50/60 1 63 61 AP20093 UVR 7100 MF HE 7100 1100 5140 2×2370 2×9,3 230 50/60 1 65 62 AP20095 UVR 8500 MF HE 8500 830 6460 2×2380 2×9,8 230 50/60 1 66 63 -
HOMOLOGATION AND INSTALLATION
Homologation
- In accordance with the 2009/125/CE Directive and Regulation no. 1253/2014 (Ecodesign 2018)
Installation and use- Ceiling, false ceiling or floor mounting
- All units can be mounted/installed outdoor when equipped with a cover.
- TECHNICAL LITERATURE
-
FAQS