Sicurgas has three warning lights: green LED – indicates that the detector works properly, yellow LED – indicates detector failure, red LED – indicates the gas presence in the environment (ALARM).
Semiconductor sensor for carbon monoxide detection.
Admissible humidity (without condensation): from 30 to 80% UR.
Unit weight: 0,41 Kg.
Electric features
Power supply: 230Vac 50Hz.
Consumption: 3 VA.
Output through electromagnetic relay.
Contacts rating: 5(3)A – 250Vac.
ADVANTAGES
0
This product is out of production.
Advantages
TECHNICAL SPECIFICATION
CODE
POWER SUPPLY
CONTACT RATING
OPERATING
TEMPERATURE
PROTECTION DEGREE
P73
230Vac - 50Hz
5(3)A - 250Vac
0 ÷ 40 °C
IP42
HOMOLOGATION AND INSTALLATION
Homologation
Complies with EN 60730-1 standards.
Installation and use
Flush mounting in 3-module 503 embedded boxes by means of 2 screws (supplied).
The detector should be fixed on the wall at a high level of approximately 150 cm from the floor.
For a correct functioning of Sicurgas P73, avoid installing the device:
– behind or under cabinets or shelves that can prevent the natural air circulation in the environment;
– near air conditioning plants (minimum distance 2 meters);
– on the vertical line of cooking units or steam sources (bathtubs, etc.);
– in places, that could be reached by spraying water, near sinks, showers, etc.
COMPATIBLE PLATES
BTICINO Axolute, Livinglight, Light, Light tech
Living VIMAR Idea, Rondò, Plana, EikoN
GEWISS Playbus e Playbus Young
AVE Banquise, Ave Yes
LEGRAND Cross.
P73 detector works with carbon monoxide concentrations considered not dangerous for an adult person in normally healthy conditions even if breathed for several hours (see: researches of U.S. Army Human Engineering Laboratory USA).
In case of danger, Sicurgas P63 immediately activates the internal alarms, the intermittent red LED and an acoustic alarm.
At the same time with the visual and acoustic alarms, operates a relay with switching contacts for controlling an aerator that brings fresh air from outside.
Sicurgas P73 is equipped with a test button for checking the system: button pressing activates a control procedure with duration of 30 seconds. During this procedure the internal and external components of the system are checked.