Suitable for laying under access ramps, parking lots, pavements and walkways.
Constant power delivered ~17 W/m.
They require control thermostats to be used.
General features
Cable composition:
– 2 conductors in solid copper and tinned copper
– Outer sheath in pvc
– Aluminium foil shielding
– Tinned copper sheath
The heating cable includes:
– 1 standard length of heating cable
– 2 cold tails
Minimum installation room temperature 5 °C
Maximum room temperature 65 °C
Minimum storage room temperature -20 ÷ -25°C
Electric features
Power supply 230V-50Hz
Constant power delivered ~17W/m
Total power absorbed at 230V:
– K17C29 510 W
– K17C73 1260 W
– K17C82 1530 W
– K17C102 1750 W
– K17C129 2200 W
ADVANTAGES
0
Suitable for laying under access ramps, parking lots, pavements and walkways.
Constant power delivered ~17 W/m.
They require control thermostats to be used.
Advantages
TECHNICAL SPECIFICATION
CODE
CABLE
LENGTH
TOTAL
POWER
ABSORBED AT 230V
HEATED
SURFACE
WITH 130W/M
MINIMUM
INSTALLATION
ROOM
TEMPERATURE
MAXIMUM
ROOM
TEMPERATURE
K17C29
30.42 m
510 W
3 m²
5 °C
65 °C
K17C73
74.28 m
1260 W
6 m²
5 °C
65 °C
K17C82
89.34 m
1530 W
7 m²
5 °C
65 °C
K17C102
101.98 m
1750 W
9 m²
5 °C
65 °C
K17C129
124.58 m
2200 W
11 m²
5 °C
65 °C
HOMOLOGATION AND INSTALLATION
Homologation
CE
Installation and use
The two ends of the cable must be connected to the phase and to the neutral in a special junction box;
Along its path, the cable must not overlap and the original length must not be cut;
It is recommended to use a sturdy flexible sheath to protect the terminals and cold tails and for the branches to be easily inspected after installation;
The cable will be laid at a depth of 50 mm in a bed of sand and cement with a serpentine path with a 100 mm pitch, therefore it is advisable to form a path by securing the cable with KJSSP spacing bars;
It is advisable to apply an insulating coating over the heating cable for a correct installation.
The heating cables consist of a coil-wound resistance on two conductors. The resistance is in contact with the conductors through splicing points at constant intervals; the energy to heat the resistance is drawn at the splicing points;
The heating cables are supplied in reels of standard length that cannot be cut or stretched;
They require L03BM1A type control thermostats.
ACCESSORIES
Code KBE3A: junction box in insulating material;
Code KSUPP-A: support foot for the KBE3A junction box;