Thermostats with capillary for rear panel mounting to adjust the water temperature in the boilers, in the airconditioning and cooling systems, in household appliances, in electrical furnaces.
General features
Knob and ring to be bought separately
Sensing element with stainless steel diaphragm.
Copper bulb and capillary.
Copper bulb and capillary, tinned for types C02C2 and C02D2.
Screws for rear panel mounting for C02C2 and C02D2.
Base in shock-proof self-extinguishing thermoplastic material V0.
Threaded connection “Faston” 6.3 mm.
ACCESSORIES
Code 2724259: control knob for C02A3
Code 2724260: control knob for C02B3
Code 2723094: control knob for C02C2
Code 2723095: control knob for C02D2
Code 2724261: control knob for C02E3
Code 2723856: control knob for C02F
Code 2554972: thermoplastic ring for control knobs
Code 2754975: stainless steel ring for control knobs
Code G23: seal cap Gc 1/2, PN10 bar, without casing.
Code G28: copper sheath Gc 1/2 PN10 bar, length 177 mm, including spring to mount the capillary.
Code 5677050: group of range limiters, used for knobs.
Electric features
Two directions microswitch of instant action with AGcdO contacts.
Contact parameters in compliance with EN 60730-1: 15(6)A 250V~ 50Hz
ADVANTAGES
0
Thermostats with capillary for rear panel mounting to adjust the water temperature in the boilers, in the airconditioning and cooling systems, in household appliances, in electrical furnaces.
Advantages
TECHNICAL SPECIFICATION
CODE
TEMPERATURE
RANGE
DIFFERENTIAL
MAXIMUM
BODY TEMPERATURE
MAXIMUM
BULB TEMPERATURE
CAPILLARY
LENGTH
C02A3
10 ÷ 90 °C
6 ± 1 K
85 °C
150 °C
1 m
C02B3
50 ÷ 300 °C
8 ± 2 K
85 °C
330 °C
1.5 m
C02C2
- 20 ÷ 40 °C
2 ± 0.5 K
85 °C
80 °C
1.5 m
C02D2
- 35 ÷ 20 °C
2 ± 0.5 K
85 °C
80 °C
1.5 m
C02E3
40 ÷ 120 °C
6 ± 2 K
85 °C
150 °C
1 m
C02F
50 ÷ 320 °C
10 ± 2 K
85 °C
330 °C
1 m
HOMOLOGATION AND INSTALLATION
Homologation
Compliance with standards EN 60947-5-1, EN 60730-1
Compliance with Directive 2014/68 / EC (PED);
ENEC certificates.
Installation and use
Rear panel mounting for the thermostat’s body.
The bulb with capillary can be mounted remotely and is provided with seal caps or copper sheath with GC 1/2 connection
When the temperature increases: 1-2 are opening, 1-4 are closing.