Self-adjusting heating cables to maintain the temperature of fluids - high temperature systems
-
DESCRIPTION
General features0
Suitable for maintaining the temperature of liquids in the pipes, for example, domestic hot water
It can maintain the pipes at a temperature above 70°C, thereby avoiding the formation of Legionellosis bacteria
Optimisation of energy consumption thanks to the self-adjusting feature of the cable
- Cable composition:
– Nickel-plated copper conductors of 1.25 mm² cross-section
– Self-adjusting conductive core
– Polyolefin insulating sheath
– Braided copper sheath
– Outer sheath in modified polyolefin - Cable length:
– K55A100 100 m
– K65A100 100 m - Maximum room temperature powered 80 °C
- Maximum room temperature not powered 100 °C
- Minimum installation room temperature -20 °C
- Minimum storage room temperature -20 ÷ -25°C
Electric features- Power supply 230V-50Hz
- Power delivered:
– K55A100 22.5 W/m at 0°C, 9 W/m at 55°C
– K65A100 31.5 W/m at 0°C, 13 W/m at 65°C
- Cable composition:
-
ADVANTAGES
0
Suitable for maintaining the temperature of liquids in the pipes, for example, domestic hot water
It can maintain the pipes at a temperature above 70°C, thereby avoiding the formation of Legionellosis bacteria
Optimisation of energy consumption thanks to the self-adjusting feature of the cable
Advantages -
TECHNICAL SPECIFICATION
-
HOMOLOGATION AND INSTALLATION
Homologation
- CSTB
- CE
Installation and use- The heating cable can be secured linearly according to the diameter of the pipe;
- The cable can be cut to the desired length directly during installation;
- Minimum bending radius: 27 mm;
- The power of a metre of cable varies with the room temperature;
- The total power depends on the length of the heating cable. The heating core is active along the entire length of the cable, therefore, a cold tail end must be created so as to have a section with cold terminals (using the KIT2A);
- Secure the cable to the pipe with the relevant fixing tape K50 for steel pipes or K50AL for plastic pipes;
- It is advisable to apply an insulating coating over the heating cable for an effective system.
- The heat emission varies automatically without control thermostats being used. They are based on the property of some polymers, with which the conductors are insulated, to vary their resistance according to the temperature which they are subjected to;
- Using a thermostat (L03BI1A) allows periodic heating of the system to be guaranteed or to maintain the system temperature constant.
ACCESSORIES
- Code KBE3A: junction box in insulating material
- Code KSUPP-A: support foot for the KBE3A junction box
- Code K50: fiberglass fixing tape for metal pipes
- Code K50AL: fixing tape for plastic pipes
- Code KIT2A: Kit to seal terminals for self-adjusting cables (for 1 cable)
- Code KFAN: labels for the presence of a heating cable
- Code L03BM1A: ON/OFF thermostat – proportional – P.I.D. at 1 outlet
- TECHNICAL LITERATURE
-